Breathalyzer Service and Calibration
Professional service and calibration of Alco-Sensor breathalyzers is provided by TransCom International. The only authorized distributor and manufacturer's service in Poland.
Comprehensive Service and Adjustment of Breathalyzers
As the only authorized manufacturer service, we offer professional quality of technical care for Alco-Sensor devices. We combine many years of experience with the most advanced diagnostic methods, providing full support at every stage of device operation.
By choosing our service, you invest in extending the life of your breathalyzer and gain certainty that every test will be carried out on a device with guaranteed correct readings, which is crucial for safety and result reliability.
Calibration
The Breath Analyzer Measurement Laboratory, operating within TransCom International, is a specialized unit with one of the longest accreditation histories in Poland. Since 2004, we have been setting standards in breath analyzer metrology.
AP 071, issued by the Polish Center for Accreditation, since 2004.
Our calibration certificates are a recognized document confirming measurement consistency.
1 Calibration / Verification
In reality, it is an exclusively comparative process that can confirm the reliability of your device.
Currently, the terms calibration and verification are treated as synonyms and mean the same metrological action. Key facts: Definition: Calibration / Verification is the establishment of a relationship between the indication of the instrument and the value of the standard (including the determination of measurement uncertainty).
Purpose: Ensuring measurement consistency, i.e., linking device results to official standards.
Result: Issuance of a calibration certificate with a table of results (reference value, average of measurements, and uncertainty).
It is worth remembering: calibration itself does not include repair or interference with the device mechanism – it is only a confirmation of its current metrological state performed under laboratory conditions.
2 Adjustment
While calibration only states the condition of the instrument, adjustment involves a specific technical action. Key facts: Definition: Adjustment is a set of actions intended to bring a measuring instrument to a state of operation consistent with its purpose and required accuracy.
Purpose: Eliminating systematic errors or minimizing them through physical or software intervention in the device mechanism.
Result: An instrument that indicates values as close as possible to the true (reference) values across the full operating range.
Remember: Adjustment is the "setting" of an instrument, after which re-calibration should always follow to confirm that the changes produced the expected effect and the device measures correctly.
3 Technical Service
It guarantees that the breathalyzer is not only functional but also safe and ready for operation in all conditions for the next 6 months with no test limit. Key facts: Definition: A set of technical activities including diagnostics, maintenance, and replacement of worn parts and components of the device, completed with adjustment and a series of accuracy tests.
Purpose: Restoring full breathalyzer functionality, extending its lifespan, properly establishing measurement characteristics, and ensuring compliance with manufacturer parameters.
Result: A device after periodic inspection, cleaning, and software update, prepared for further, trouble-free operation.
Remember: Only service performed by manufacturer-authorized specialists for a given model using only original spare parts ensures the device retains its technical parameters and does not fail at a critical moment.
Why Us?
PCA Accreditation
PCA Accreditation Certificate AP 071 since 2004 compliant with PN-EN ISO/IEC 17025:2018-02
Authorized Service
The only distributor and manufacturer's service in Poland - Intoximeters
Original Parts
Exclusive access to original manufacturer components
30+ Years Experience
We specialize in Alco-Sensor breathalyzers since 1995
Wet Ethanol Standards CRM
Certified Reference Material for precise adjustment, calibration, and verification of breathalyzers
Dry Ethanol Gases
Certified gas mixtures for precise adjustment, calibration, and verification of breathalyzers
Our Services
Calibration
Professional calibration of breathalyzers with the issuance of a calibration certificate compliant with PN-EN ISO/IEC 17025:2018-02. PCA Accreditation No. AP 071
Repair
Service and repair of breathalyzers using only original parts in accordance with the manufacturer's procedure
Maintenance
Regular maintenance ensuring long device lifespan
Diagnostics
Comprehensive device diagnostics with defect identification and repair recommendations
Expert Assessment
Professional technical assessment of device condition with detailed documentation
Accuracy Tests
Series of tests verifying the correctness and accuracy of breathalyzer readings
Wet Ethanol Standards CRM
Certified Reference Material (CRM) (PCA Accreditation No. RM 007:ISO 17034) for precise adjustment, calibration, and verification of breathalyzer measurements
Dry Ethanol Gases
Certified gas mixtures (ethanol with nitrogen) used for precise adjustment, calibration, and verification of breathalyzer measurements